Digital Mammography System AMULET Innovality with Bellus Workstation
Key Features :
- Fujifilm unique technology (Dedicated mammography AWS)
- Tomosynthesis, High Quality Image for easier diagnosis
- Advance Biopsy System
- Amulet Harmony, Easy operation and patient comfort.
AMULET BELLUS II, a multimodality workstation with multiple idea functions for mammography. a smart mammography workstation for streamlined workflow and percise diagnosis. Support for users in conducting diagnosis with reading protocols tailored to mammographic diagnosis and smooth image displays. Customization for reading protocols includes configuration for making comparisons of current and prior images and for S-views synthesized from tomosynthesized images of AMULET Innovality
High Performance X-ray Detection
- X-ray conversion method Direct-conversion
- X-ray comversion material a-Se
- Detector Hexagonal Pixel
- Effective image area (on the flat panel sensor) 236.4 mm (vertical) x 296.4 mm (horizontal) (9.31 in. x 11.7 in.)
- Pixel resolution 50 x 50 μm/pix
Generator x-ray Tube
- Tube voltage range 22 kV to 49 kV (1 kV intervals)
- Tube voltage accuracy ±1 kV
- mAs setting range Large focus: 2 mAs to 600 mAs, Small focus: 2 mAs to 300 mAs
- mAs setting precision ±10% +0.2 mAs
- Anode angle Large focus: 16°, Small focus: 10°
- Anode material Tungsten (W/Re)
- X-ray leakage radiation < 100 mR/h (49 kV at a distance of 1 m (39.4 in))
- Total filtration of X-ray generator 0.7 mmAl
- Total filtration of tube assembly 0.63 mm Be
Swivel arm
- Vertical travel 690 mm to 1,500 mm (27.2 in. to 59.1 in.) (height of the exposure table at 0º)
- Rotation +190° to -190°
- SID 650 mm (25.6 in.)
Compression Modes
- Electric Compression 0 N to 200 N, 0 N to 200 N (+190° to +50°, -50° to -190°)
- Manual Compression 0 N to 230 N (+50° to -50°)
Grid
- Moving focused grid Aspect ratio 6:1 41 lines/cm, Film material: Pb, intermediate material: fiber
Biopsy Positioner Function
- Image size 70 mm x 60 mm (2.75 in. x 2.36 in.) (Top surface of the exposure table)
- Positioner drive system Electric (AUTO, Manual)
- Positioner weight 5.5 kg (12.13 lb) or less
- Stereo angle ±15º
Bellus Workstation
- Main Control Unit 4 cores (or more) processor
16GB RAM or above
Amulet Innovality Tomosynthesis Biopsy With Bellus Workstation Configuration
- Digital Mammography Foot Switch
- Compression Plate
- Mag Table
- Control Desk
- Workstation / Console Advance
- Protect Board
- Monitor Arm
- Anchor Plate
- Medical Monitor Grade
- 1 Shot Panthom
- QC Test Software
- Positioner Biopsy Kit
- Compression Plate 2D Biopsy
- Needle Guide
- Needle Guide Cover
- Dicom Printer
- Switch Hub
- Access Point
- UPS for Console Advance
- Bellus Workstation
- Medical Monitor Grade for Bellus Workstation
- Mouse / Controller for Bellus