COMPASS

 iCare COMPASS Automated Tracked Perimetry
 Key features :
  • Standard automated perimetry with standard 24-2, 30-2 and 10-2 visual field testing with ZEST Fast, ZEST and full threshold strategies
  • Active retinal tracking compensates for poor patient fixation in real-time
  • Auto-focus — no trial lens needed
  • Hygienic design
  • Illustrative fixation analysis; fixation area and plot
  • TrueColor confocal imaging up to 100° with SmartMosaic
  • No dilation of pupil needed, the patient can blink freely and the test can be suspended at any time without data loss
  • Ease of use & minimal operator training
  • Smart Progression Analysis provides more information on the changes of the visual field over time
iCare COMPASS Automated Perimeter with Active Retinal Tracking

Bringing the visual field analysis to the next level Automated Tracked Perimetry overcomes limitations in visual field testing when compared to Standard Automated Perimetry (SAP). iCare COMPASS® is an automated perimeter combined with an active retinal tracker and a scanning ophthalmoscope. This advanced technology provides retinal sensitivity and fixation analysis, as well as TrueColor Confocal imaging of the retina.

Fundus Perimetry
  • Projection field30° (radius)
  • Background luminance31.4 asb
  • Maximum luminance10000 asb
  • Dynamic range0 – 50 dB
  • Stimulus sizeGoldmann III, round, white
  • Stimulus duration200 ms
  • Test StrategiesZEST Fast, ZEST, 4-2 (full threshold), Suprathreshold, Quick Suprathreshold
  • Threshold tests30-2, 24-2, 10-2
  • Fixation control25 Hz automated retinal tracking
Fundus Imaging
  • Field of view60° (diameter) 100° horizontal montage of three 60° images (SmartMosaic)
  • Sensor resolution5 Mpixel (2592×1944)
  • Light sourceinfrared (825-870 nm) and white LED (440-650 nm)
  • Imaging modalitiescolor, infrared, red-free, stereoscopic, SmartMosaic
  • Resolution17 microns
Dimensions
  • Weight25 Kg
  • SizeW 360 mm x D 620 mm x H 590 mm
Electrical requirements
  • Power100-240 VAC, 50-60 Hz
  • Consumption80 W
Other Features
  • Automatic operationauto-alignment, auto-focus, auto-retinal tracking, auto-pupil tracking, auto-exposure, auto-capture
  • Non-mydriatic operationminimum pupil size 3 mm
  • Working distance28 mm
  • Auto-focusing adjustment range-12D to +15D
  • User interfaceTablet operated, with multi-touch, color display
  • ConnectivityEthernet connection
  • DICOMDICOM support (DICOM file export), DICOM communication (modality worklist)
  • Hard diskSSD, 480 GB or higher