{"version":"1.0","provider_name":"PT. MAJU JAYA MEDIKA","provider_url":"https:\/\/ptmajujayamedika.co.id","author_name":"majujayamedika","author_url":"https:\/\/ptmajujayamedika.co.id\/index.php\/author\/majujayamedika\/","title":"APERTO LUCENT MR Imaging System - PT. MAJU JAYA MEDIKA","type":"rich","width":600,"height":338,"html":"<blockquote class=\"wp-embedded-content\" data-secret=\"y4x6PknFvq\"><a href=\"https:\/\/ptmajujayamedika.co.id\/index.php\/aperto-lucent-mr-imaging-system\/\">APERTO LUCENT MR Imaging System<\/a><\/blockquote><iframe sandbox=\"allow-scripts\" security=\"restricted\" src=\"https:\/\/ptmajujayamedika.co.id\/index.php\/aperto-lucent-mr-imaging-system\/embed\/#?secret=y4x6PknFvq\" width=\"600\" height=\"338\" title=\"&#8220;APERTO LUCENT MR Imaging System&#8221; &#8212; PT. MAJU JAYA MEDIKA\" data-secret=\"y4x6PknFvq\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\" class=\"wp-embedded-content\"><\/iframe><script type=\"text\/javascript\">\n\/* <![CDATA[ *\/\n\/*! This file is auto-generated *\/\n!function(d,l){\"use strict\";l.querySelector&&d.addEventListener&&\"undefined\"!=typeof URL&&(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&&!\/[^a-zA-Z0-9]\/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret=\"'+t.secret+'\"]'),o=l.querySelectorAll('blockquote[data-secret=\"'+t.secret+'\"]'),c=new RegExp(\"^https?:$\",\"i\"),i=0;i<o.length;i++)o[i].style.display=\"none\";for(i=0;i<a.length;i++)s=a[i],e.source===s.contentWindow&&(s.removeAttribute(\"style\"),\"height\"===t.message?(1e3<(r=parseInt(t.value,10))?r=1e3:~~r<200&&(r=200),s.height=r):\"link\"===t.message&&(r=new URL(s.getAttribute(\"src\")),n=new URL(t.value),c.test(n.protocol))&&n.host===r.host&&l.activeElement===s&&(d.top.location.href=t.value))}},d.addEventListener(\"message\",d.wp.receiveEmbedMessage,!1),l.addEventListener(\"DOMContentLoaded\",function(){for(var e,t,s=l.querySelectorAll(\"iframe.wp-embedded-content\"),r=0;r<s.length;r++)(t=(e=s[r]).getAttribute(\"data-secret\"))||(t=Math.random().toString(36).substring(2,12),e.src+=\"#?secret=\"+t,e.setAttribute(\"data-secret\",t)),e.contentWindow.postMessage({message:\"ready\",secret:t},\"*\")},!1)))}(window,document);\n\/\/# sourceURL=https:\/\/ptmajujayamedika.co.id\/wp-includes\/js\/wp-embed.min.js\n\/* ]]> *\/\n<\/script>\n","description":"APERTO LUCENT MR Imaging System\u00a0 Key Features : Making MRI affordable Ease of Installation Small Footprint Description Technical Data APERTO Lucent, An open permanent MRI system with a magnetic field strength of 0.4T.\u00a0ECHELON Smart heralds the dawn of a new standard for 1.5T superconductive MRI.APERTO Lucent offers sophisticated MR imaging through a permanent magnet with 0.4T static field strength together with a compact gantry. Our technological expertise enabled the design and creation of a single-pillar MRI structure which offers premium open space.\u00a0 Our magnetic circuit technology and unparalleled diagnostic functions enable crisp, high-definition imaging of clinically challenging regions and applications.Enhanced operability supports efficient and reliable diagnosis, together with ease of operation and image sharing capabilitie. Low running costs together with an attractive initial investment accelerate your MRI business and offer an excellent return on investment In permanent magnet Open MRI technology, the magnetic field remains strong over the years with barely any change.Unlike superconductive MRI, there is no need for additional equipment and infrastructure in order to maintain the magnetic field, thereby keeping the costs low.A low capacity power supply means the initial power system cost can be kept low, and lowering energy consumption reduces monthly running costs too.The APERTO Lucent does not require a cooling system negating the need for a complex and costly infrastructure and the installation area can be minimized as a result.Reduced construction costs with easy siting,\u00a0MRI installation usually includes two types of shielding: RF shielding to block any high frequency noise from the outside and magnetic shielding to suppress leakage of the magnetic field from the inside. However, a permanent magnet MRI system generally does not require any specific magnetic shielding, so the cost of construction is reduced.Removing many of the construction processes usually associated with superconductive systems, results in faster and easier installation ensuring your Open MRI is up and running in a shorter timeframe. APERTO Lucent&#8217;s compact design significantly reduces the space required for installationAPERTO Lucent consists of three main units: the gantry, console and power supply system; fewer than its superconductive counterpart.The magnetic field leakage is also kept low, and in turn, the imaging room can be small.As an equipment room is unnecessary, the overall footprint is reduced and the space saved can be used for other purposes.\u00a0 \u00a0 Spesification Imaged region Whole body Image reconstruction method 2D\/3D Fourier Imaged nucleus Hydrogen (Proton) Basic imaing system\u00a0 Spin Echo\uff08Proton Density Weighted Image, T1\/T2 Weighted Image\uff09, Inversion Recovery Imaging\uff08T1 Weighed Image\uff09, Gradient Echo Image\uff08T1\/T2* Weighed Image\uff09, Fast Spin Echo Image\uff08Proton Density Weighed Image, T1\/T2 Weighed Image\uff09, Fast Inversion Recovery Image\uff08T1\/T2 Weighed Image\uff09, MR Angiography Image\uff08TOF, PC\uff09Echo Planner Image (EPI) Artifact Suppression \/ Removal softwarePhase\/FrequencyPre-SaturationECG GatingPulse GatingRespiration Slice thickness0.4\uff5e100mm Slice plane, Axial Plane\uff08Axial\uff09Sagittal Plane\uff08Sagittal\uff09Coronal Plane\uff08Coronal\uff09Double Oblique Plane(Oblique Plane)Multi-angle planeMulti-plane\u00a0 Soft Sound\u00a0 Scan Matrix \uff0832\u301c1024\uff09x\uff0832\u301c1024\uff09x\uff082\u301c512\uff09 Multi-slice Maximum 256 Multi-echo Maximum 32 FOV 5\uff5e350mm\u00a0 Magnetic Field System Magnetic strength 0,4 T Gradien magnetic field system Magnetic strength 25mT\/m Image processing\/display system Central processing unit CPU 33,3 GHz or higher Memmory 8 GB or More Magnetic disk unit Fixed disk system: 320GB or more DVD-R\/+R Rewritable type: 4.7GB Image reconstruction matrix Upto 2048 \u00d7 204818000 images\/sec*(256 x 256 matrix)* Depends on its circumstances. Display matrix 1024&#215;1024 Display Monitor 24\u201d color LCD monitor(Display matrix: 1920 \u00d7 1200) Patient table Table width(Tabletop width) 730 mm (Table Top width 700 mm)\u00a0 vertical motion\u00a0 (450mm to 857mm) Longitudinal\/lateral travel Yes, longitudinal :1800mm, lateral :+\/-150mm Movement Motor Driven(Manual Also) Maximum patient weight Maximum 240kg (in case of manual movement) Power Requirements Single-phase 200\/208\/220\/230\/240VAC\u00b110%, 9.5kVA 3 phase AC, 380\/400\/415V +\/- 10% 50Hz, 400\/460\/480V+\/- 10% 60Hz Power supply frequency4kWH Other Warranty 3 years (Fujifilm unit only) Installation Included Training \u00a0 APERTO Lucent, An open permanent MRI system with a magnetic field strength of 0.4T.\u00a0ECHELON Smart heralds the dawn of a new standard for 1.5T superconductive MRI.APERTO Lucent offers sophisticated MR imaging through a permanent magnet with 0.4T static field strength together with a compact gantry. Our technological expertise enabled the design and creation of a single-pillar MRI structure which offers premium open space.\u00a0 Our magnetic circuit technology and unparalleled diagnostic functions enable crisp, high-definition imaging of clinically challenging regions and applications.Enhanced operability supports efficient and reliable diagnosis, together with ease of operation and image sharing capabilitie. Low running costs together with an attractive initial investment accelerate your MRI business and offer an excellent return on investment In permanent magnet Open MRI technology, the magnetic field remains strong over the years with barely any change.Unlike superconductive MRI, there is no need for additional equipment and infrastructure in order to maintain the magnetic field, thereby keeping the costs low.A low capacity power supply means the initial power system cost can be kept low, and lowering energy consumption reduces monthly running costs too.The APERTO Lucent does not require a cooling system negating the need for a complex and costly infrastructure and the installation area can be minimized as a result.Reduced construction costs with easy siting,\u00a0MRI installation usually includes two types of shielding: RF shielding to block any high frequency noise from the outside and magnetic shielding to suppress leakage of the magnetic field from the inside. However, a permanent magnet MRI system generally does not require any specific magnetic shielding, so the cost of construction is reduced.Removing many of the construction processes usually associated with superconductive systems, results in faster and easier installation ensuring your Open MRI is up and running in a shorter timeframe. APERTO Lucent&#8217;s compact design significantly reduces the space required for installationAPERTO Lucent consists of three main units: the gantry, console and power supply system; fewer than its superconductive counterpart.The magnetic field leakage is also kept low, and in turn, the imaging room can be small.As an equipment room is unnecessary, the overall footprint is reduced and the space saved can be used for other purposes.\u00a0 \u00a0 Spesification Imaged region Whole body Image reconstruction method 2D\/3D Fourier Imaged nucleus Hydrogen (Proton) Basic imaing system\u00a0 Spin Echo\uff08Proton Density Weighted Image, T1\/T2 Weighted Image\uff09, Inversion Recovery Imaging\uff08T1 Weighed Image\uff09, Gradient Echo Image\uff08T1\/T2* Weighed Image\uff09, Fast","thumbnail_url":"https:\/\/ptmajujayamedika.co.id\/wp-content\/uploads\/2025\/03\/APERTO-LUCENT-MR-Imaging-System.png"}