<?xml version="1.0"?>
<oembed><version>1.0</version><provider_name>PT. MAJU JAYA MEDIKA</provider_name><provider_url>https://ptmajujayamedika.co.id</provider_url><author_name>majujayamedika</author_name><author_url>https://ptmajujayamedika.co.id/index.php/author/majujayamedika/</author_url><title>Whole Body X-ray CT System Scenaria View Plus 128 Slice with SynergyDrive Plus - PT. MAJU JAYA MEDIKA</title><type>rich</type><width>600</width><height>338</height><html>&lt;blockquote class="wp-embedded-content" data-secret="47whOfnHDJ"&gt;&lt;a href="https://ptmajujayamedika.co.id/index.php/elementor-6047/"&gt;Whole Body X-ray CT System Scenaria View Plus 128 Slice with SynergyDrive Plus&lt;/a&gt;&lt;/blockquote&gt;&lt;iframe sandbox="allow-scripts" security="restricted" src="https://ptmajujayamedika.co.id/index.php/elementor-6047/embed/#?secret=47whOfnHDJ" width="600" height="338" title="&#x201C;Whole Body X-ray CT System Scenaria View Plus 128 Slice with SynergyDrive Plus&#x201D; &#x2014; PT. MAJU JAYA MEDIKA" data-secret="47whOfnHDJ" frameborder="0" marginwidth="0" marginheight="0" scrolling="no" class="wp-embedded-content"&gt;&lt;/iframe&gt;&lt;script type="text/javascript"&gt;
/* &lt;![CDATA[ */
/*! This file is auto-generated */
!function(d,l){"use strict";l.querySelector&amp;&amp;d.addEventListener&amp;&amp;"undefined"!=typeof URL&amp;&amp;(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&amp;&amp;!/[^a-zA-Z0-9]/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret="'+t.secret+'"]'),o=l.querySelectorAll('blockquote[data-secret="'+t.secret+'"]'),c=new RegExp("^https?:$","i"),i=0;i&lt;o.length;i++)o[i].style.display="none";for(i=0;i&lt;a.length;i++)s=a[i],e.source===s.contentWindow&amp;&amp;(s.removeAttribute("style"),"height"===t.message?(1e3&lt;(r=parseInt(t.value,10))?r=1e3:~~r&lt;200&amp;&amp;(r=200),s.height=r):"link"===t.message&amp;&amp;(r=new URL(s.getAttribute("src")),n=new URL(t.value),c.test(n.protocol))&amp;&amp;n.host===r.host&amp;&amp;l.activeElement===s&amp;&amp;(d.top.location.href=t.value))}},d.addEventListener("message",d.wp.receiveEmbedMessage,!1),l.addEventListener("DOMContentLoaded",function(){for(var e,t,s=l.querySelectorAll("iframe.wp-embedded-content"),r=0;r&lt;s.length;r++)(t=(e=s[r]).getAttribute("data-secret"))||(t=Math.random().toString(36).substring(2,12),e.src+="#?secret="+t,e.setAttribute("data-secret",t)),e.contentWindow.postMessage({message:"ready",secret:t},"*")},!1)))}(window,document);
//# sourceURL=https://ptmajujayamedika.co.id/wp-includes/js/wp-embed.min.js
/* ]]&gt; */
&lt;/script&gt;
</html><description>Whole Body X-ray CT System Scenaria View Plus 128 Slice with SynergyDrive Plus Key Features : High speed &amp; Quality Has Advance Function Has other function such as touch vision provides a comfortable examination and breath guide to helps&#xA0; the patient&#xA0; during the scan Description Technical Data SCENARIA View is a powerful premium performance CT solution that provides dependable routine application capabilities with available advanced clinical modules for Interventional CT, extended coverage Shuttle Scanning (for Perfusion Exams), Cardiac CTA and Dual Energy examinations. The View employs 64 discrete detector and electronics channels over a 40mm detector coverage and reconstructs&#xA0; up to 128-slices per scan rotation. Unique and clinically valuabel capabilities of the view include: Fujifilm&#x2019;s Next Generation Vision Model based Iterative Reconstruction capability &#x201C;Intelli IPV&#x201D; that can provide dose reduction up to 83% at the same image quality*. A wider 80cm gantry aperture, a more powerful 84kW generator provides up to 700mA operation. The advantages of the standard Auto Lateral Shift Table enables &#xB1;10cm lateral shift (20cm total shift range) providing easier and more accurate positioning of the patient&#x2019;s anatomy of interest at the scan Field of View&#x2019;s iso-center where spatial resolution is better than off-center. HiMAR Plus metal artifact reduction minimizes objectionable metal induced artifacts. The View includes XR-25 Dose-Check control and is XR-29 Smart-Dose Compliant, while providing FDA 510(k) Cleared Indication for use for Low-Dose CT lung Cancer Screening. Standard Configuration Scanner Gantry Patient Table Operator&#x2019;s Console Standard accessories&#xA0; Injector printer workstation ECG Monitor UPS Table Set&#xA0; Instalation Uji kesesuaian&#xA0; Training&#xA0; Warranty 3 years Fujifilm system only Gantry/Detector&#xA0; Geometry Continuously rotating, slip ring 360 Detector Type Solid state 64 channel detector Physical Detectors Rows 64 Rows Max.Number of slice per rotation 128 slices Scan times, sec. 0.35 sec No of channels 888 ch Scan times, sec. 0.35 , 0.4 , 0.5 , 0.75 , 1.0 , 2.0 sec Smallest Slice thickness, mm 0.625 mm Detector width 40 mm Gantry tilt, 0 &#xB1;30&#xB0; Gantry aperture, cm 800 mm Scan localizer Laser Control of gantry movement from console Yes Detector scintillator + photodiode Detector Geometry (tube -detector) 1,072 mm Maximum Table pitch 1.578 Fastest whole body scanning 9.4 sec @ 1,700 mm, 0.35 sec/scan, pitch 1.578 Gantry thickness 880 mm Gantry display Patient name, ECG wave, gantry position, Scan Guidance Gantry Sub display for patient 3 displays Multi lanuguage display for patient 11 languages Gantry panel available Gantry cooling method air cooling Number of elements 56,832 elements X-ray Tube&#xA0; Heat storage , MHU(100% Usage) 7.5 MHU Heat dissipation rate , MHU/min 1.386 MHU/min Guranteed Tube life Available Cooling TypeHybrid cooling (glycol water-cooling or oil coling on target) Focal spot 0.7 x 0.8 mm / 1.2 x 1.4 mm X-ray Generator KW output 72 KW KVp range 80,100,120,140 KV mA range 10&#xFF5E;600 mA (5mA step) mA dose reduction function available Scanning Ability Max Scan Time, Sec 100 sec Max scan volume 170 cm Max Scan Length 175 cm Max scan volume, cm (Sliding Table +Extension OP) 195 cm Max scan Lenge, cm (Sliding Table +Extension OP) 200 cm Possibility of multislice scan with gantry tilt Yes (Normal) or No (Helical) Recon struction time / image , sec max 60 images/Sec Cardiac Scanning&#xA0; Fastest rotation speed 0.35 sec/rotation Number of segments depends on heart beat Patient Table Movement Vertical , cm 45.0 cm-105.0 cm Longitudinal , cm 211.0 cm Spiral Scanable range , cm 175.0 cm ( with tabletop extension) Max load capacity, kg 230 kg Image Processing Reconstruction matrixes 512 x 512 Reconstruction time/slice, sec 18 images/Sec Display Monitor size Wide 24&#x2033;LCD Matrices, Pixels 1920 x 1200 Image Enlargement Variable Max. no of slice display at once 25 images Image Storage&#xA0; Hard Disk , Image (over 2TB, over 600,000 images)Raw Data (over 3TB, over 6,000 scans) No of online images (512&#xD7;512) 200,000 images over Archival Storage DVD-RAM, DVD-R/RW, CD-R/RW Read and write CD on main console&#xA0; Other CEV CPR 3D Voxel transmission adaptive filter &amp; mA predict scan&#xA0; viewer for media archiving recovery intelli ec dicom print Post Processing work station Workstation,CPU, Hardisk, LCD Monitor&#xA0; Workstation Software SCENARIA View is a powerful premium performance CT solution that provides dependable routine application capabilities with available advanced clinical modules for Interventional CT, extended coverage Shuttle Scanning (for Perfusion Exams), Cardiac CTA and Dual Energy examinations. The View employs 64 discrete detector and electronics channels over a 40mm detector coverage and reconstructs&#xA0; up to 128-slices per scan rotation. Unique and clinically valuabel capabilities of the view include: Fujifilm&#x2019;s Next Generation Vision Model based Iterative Reconstruction capability &#x201C;Intelli IPV&#x201D; that can provide dose reduction up to 83% at the same image quality*. A wider 80cm gantry aperture, a more powerful 84kW generator provides up to 700mA operation. The advantages of the standard Auto Lateral Shift Table enables &#xB1;10cm lateral shift (20cm total shift range) providing easier and more accurate positioning of the patient&#x2019;s anatomy of interest at the scan Field of View&#x2019;s iso-center where spatial resolution is better than off-center. HiMAR Plus metal artifact reduction minimizes objectionable metal induced artifacts. The View includes XR-25 Dose-Check control and is XR-29 Smart-Dose Compliant, while providing FDA 510(k) Cleared Indication for use for Low-Dose CT lung Cancer Screening. Standard Configuration Scanner Gantry Patient Table Operator&#x2019;s Console Standard accessories&#xA0; Injector printer workstation ECG Monitor UPS Table Set&#xA0; Instalation Uji kesesuaian&#xA0; Training&#xA0; Warranty 3 years Fujifilm system only Gantry/Detector&#xA0; Geometry Continuously rotating, slip ring 360 Detector Type Solid state 64 channel detector Physical Detectors Rows 64 Rows Max.Number of slice per rotation 128 slices Scan times, sec. 0.35 sec No of channels 888 ch Scan times, sec. 0.35 , 0.4 , 0.5 , 0.75 , 1.0 , 2.0 sec Smallest Slice thickness, mm 0.625 mm Detector width 40 mm Gantry tilt, 0 &#xB1;30&#xB0; Gantry aperture, cm 800 mm Scan localizer Laser Control of gantry movement from console Yes Detector scintillator + photodiode Detector Geometry (tube -detector) 1,072 mm Maximum Table pitch 1.578 Fastest whole body scanning 9.4 sec @ 1,700 mm, 0.35 sec/scan, pitch 1.578 Gantry thickness 880 mm</description><thumbnail_url>https://ptmajujayamedika.co.id/wp-content/uploads/2025/03/SCENARIA-View-Whole-body-X-ray-CT-system-64-Slice.png</thumbnail_url></oembed>
