<?xml version="1.0"?>
<oembed><version>1.0</version><provider_name>PT. MAJU JAYA MEDIKA</provider_name><provider_url>https://ptmajujayamedika.co.id</provider_url><author_name>majujayamedika</author_name><author_url>https://ptmajujayamedika.co.id/index.php/author/majujayamedika/</author_url><title>Amulet Bellus II - PT. MAJU JAYA MEDIKA</title><type>rich</type><width>600</width><height>338</height><html>&lt;blockquote class="wp-embedded-content" data-secret="DtbL2FE54A"&gt;&lt;a href="https://ptmajujayamedika.co.id/index.php/amulet-bellus-ii/"&gt;Amulet Bellus II&lt;/a&gt;&lt;/blockquote&gt;&lt;iframe sandbox="allow-scripts" security="restricted" src="https://ptmajujayamedika.co.id/index.php/amulet-bellus-ii/embed/#?secret=DtbL2FE54A" width="600" height="338" title="&#x201C;Amulet Bellus II&#x201D; &#x2014; PT. MAJU JAYA MEDIKA" data-secret="DtbL2FE54A" frameborder="0" marginwidth="0" marginheight="0" scrolling="no" class="wp-embedded-content"&gt;&lt;/iframe&gt;&lt;script type="text/javascript"&gt;
/* &lt;![CDATA[ */
/*! This file is auto-generated */
!function(d,l){"use strict";l.querySelector&amp;&amp;d.addEventListener&amp;&amp;"undefined"!=typeof URL&amp;&amp;(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&amp;&amp;!/[^a-zA-Z0-9]/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret="'+t.secret+'"]'),o=l.querySelectorAll('blockquote[data-secret="'+t.secret+'"]'),c=new RegExp("^https?:$","i"),i=0;i&lt;o.length;i++)o[i].style.display="none";for(i=0;i&lt;a.length;i++)s=a[i],e.source===s.contentWindow&amp;&amp;(s.removeAttribute("style"),"height"===t.message?(1e3&lt;(r=parseInt(t.value,10))?r=1e3:~~r&lt;200&amp;&amp;(r=200),s.height=r):"link"===t.message&amp;&amp;(r=new URL(s.getAttribute("src")),n=new URL(t.value),c.test(n.protocol))&amp;&amp;n.host===r.host&amp;&amp;l.activeElement===s&amp;&amp;(d.top.location.href=t.value))}},d.addEventListener("message",d.wp.receiveEmbedMessage,!1),l.addEventListener("DOMContentLoaded",function(){for(var e,t,s=l.querySelectorAll("iframe.wp-embedded-content"),r=0;r&lt;s.length;r++)(t=(e=s[r]).getAttribute("data-secret"))||(t=Math.random().toString(36).substring(2,12),e.src+="#?secret="+t,e.setAttribute("data-secret",t)),e.contentWindow.postMessage({message:"ready",secret:t},"*")},!1)))}(window,document);
//# sourceURL=https://ptmajujayamedika.co.id/wp-includes/js/wp-embed.min.js
/* ]]&gt; */
&lt;/script&gt;
</html><description>AMULET BELLUS II&#xA0; Key Features : Multimodality (MG/US/MRI/CT/DX/CR/RI) Has Imaging Modalities&#xA0; Has Unique Functions (Snapshot function) Other Functions&#xA0; (Printing function, &amp; work list) Description Technical Data AMULET BELLUS II, a multimodality workstation with multiple idea functions for mammography. a smart mammography workstation for streamlined workflow and percise diagnosis. Support for users in conducting diagnosis with reading protocols tailored to mammographic diagnosis and smooth image displays. Customization for reading protocols includes configuration for making comparisons of current and prior images and for S-views synthesized from tomosynthesized images of AMULET Innovality High Performance X-ray Detection X-ray conversion method Direct-conversion X-ray comversion material a-Se Detector Hexagonal Pixel Effective image area (on the flat panel sensor) 236.4 mm (vertical) x 296.4 mm (horizontal) (9.31 in. x 11.7 in.) Pixel resolution 50 x 50 &#x3BC;m/pix Generator x-ray Tube Tube voltage range 22 kV to 49 kV (1 kV intervals) Tube voltage accuracy &#xB1;1 kV mAs setting range Large focus: 2 mAs to 600 mAs, Small focus: 2 mAs to 300 mAs mAs setting precision &#xB1;10% &#xFF0B;0.2 mAs Anode angle Large focus: 16&#xB0;, Small focus: 10&#xB0; Anode material Tungsten (W/Re) X-ray leakage radiation &lt; 100 mR/h (49 kV at a distance of 1 m (39.4 in)) Total filtration of X-ray generator 0.7 mmAl Total filtration of tube assembly 0.63 mm Be Swivel arm Vertical travel 690 mm to 1,500 mm (27.2 in. to 59.1 in.) (height of the exposure table at 0&#xBA;) Rotation +190&#xB0; to -190&#xB0; SID 650 mm (25.6 in.) Compression Modes Electric Compression 0 N to 200 N, 0 N to 200 N (+190&#xB0; to &#xFF0B;50&#xB0;, &#xFF0D;50&#xB0; to &#xFF0D;190&#xB0;) Manual Compression 0 N to 230 N (&#xFF0B;50&#xB0; to &#xFF0D;50&#xB0;) &#xA0;Grid Moving focused grid Aspect ratio 6:1 41 lines/cm, Film material: Pb, intermediate material: fiber Tomo Tomosynthesis Exposure angle ST mode : &#xB1;7.5&#xB0;HR mode : &#xB1;20&#xB0; Output pixel size (slice image/S-View (optional)) ST mode: 150 um x 150 um (100 um x 100 um can also be set)HR mode: 100 um x 100 um (50 um x 50 um can also be set) Exposure time ST mode: Approx. 4 secondsHR mode: Approx. 9 seconds Biopsy Positioner Function Image size 70 mm x 60 mm (2.75 in. x 2.36 in.) (Top surface of the exposure table) Positioner drive system Electric (AUTO, Manual) Positioner weight 5.5 kg (12.13 lb) or less Stereo angle &#xB1;15&#xBA; Bellus Workstation Main Control Unit 4 cores (or more) processor16GB RAM or above Amulet Innovality Tomosynthesis Biopsy With Bellus Workstation Configuration Digital Mammography Foot Switch Compression Plate Mag Table Control Desk Workstation / Console Advance Protect Board Monitor Arm Anchor Plate Medical Monitor Grade 1 Shot Panthom QC Test Software 3D Tomosynthesis Positioner Biopsy Kit Compression Plate 2D Biopsy Needle Guide Needle Guide Cover Dicom Printer Switch Hub Access Point UPS for Console Advance Bellus Workstation Medical Monitor Grade for Bellus Workstation Mouse / Controller for Bellus Total size:&#xA0; 560 mm x 1285 mm&#xA0; AMULET BELLUS II, a multimodality workstation with multiple idea functions for mammography. a smart mammography workstation for streamlined workflow and percise diagnosis. Support for users in conducting diagnosis with reading protocols tailored to mammographic diagnosis and smooth image displays. Customization for reading protocols includes configuration for making comparisons of current and prior images and for S-views synthesized from tomosynthesized images of AMULET Innovality High Performance X-ray Detection X-ray conversion method Direct-conversion X-ray comversion material a-Se Detector Hexagonal Pixel Effective image area (on the flat panel sensor) 236.4 mm (vertical) x 296.4 mm (horizontal) (9.31 in. x 11.7 in.) Pixel resolution 50 x 50 &#x3BC;m/pix Generator x-ray Tube Tube voltage range 22 kV to 49 kV (1 kV intervals) Tube voltage accuracy &#xB1;1 kV mAs setting range Large focus: 2 mAs to 600 mAs, Small focus: 2 mAs to 300 mAs mAs setting precision &#xB1;10% &#xFF0B;0.2 mAs Anode angle Large focus: 16&#xB0;, Small focus: 10&#xB0; Anode material Tungsten (W/Re) X-ray leakage radiation &lt; 100 mR/h (49 kV at a distance of 1 m (39.4 in)) Total filtration of X-ray generator 0.7 mmAl Total filtration of tube assembly 0.63 mm Be Swivel arm Vertical travel 690 mm to 1,500 mm (27.2 in. to 59.1 in.) (height of the exposure table at 0&#xBA;) Rotation +190&#xB0; to -190&#xB0; SID 650 mm (25.6 in.) Compression Modes Electric Compression 0 N to 200 N, 0 N to 200 N (+190&#xB0; to &#xFF0B;50&#xB0;, &#xFF0D;50&#xB0; to &#xFF0D;190&#xB0;) Manual Compression 0 N to 230 N (&#xFF0B;50&#xB0; to &#xFF0D;50&#xB0;) &#xA0;Grid Moving focused grid Aspect ratio 6:1 41 lines/cm, Film material: Pb, intermediate material: fiber Tomo Tomosynthesis Exposure angle ST mode : &#xB1;7.5&#xB0;HR mode : &#xB1;20&#xB0; Output pixel size (slice image/S-View (optional)) ST mode: 150 um x 150 um (100 um x 100 um can also be set)HR mode: 100 um x 100 um (50 um x 50 um can also be set) Exposure time ST mode: Approx. 4 secondsHR mode: Approx. 9 seconds Biopsy Positioner Function Image size 70 mm x 60 mm (2.75 in. x 2.36 in.) (Top surface of the exposure table) Positioner drive system Electric (AUTO, Manual) Positioner weight 5.5 kg (12.13 lb) or less Stereo angle &#xB1;15&#xBA; Bellus Workstation Main Control Unit 4 cores (or more) processor16GB RAM or above Amulet Innovality Tomosynthesis Biopsy With Bellus Workstation Configuration Digital Mammography Foot Switch Compression Plate Mag Table Control Desk Workstation / Console Advance Protect Board Monitor Arm Anchor Plate Medical Monitor Grade 1 Shot Panthom QC Test Software 3D Tomosynthesis Positioner Biopsy Kit Compression Plate 2D Biopsy Needle Guide Needle Guide Cover Dicom Printer Switch Hub Access Point UPS for Console Advance Bellus Workstation Medical Monitor Grade for Bellus Workstation Mouse / Controller for Bellus Total size:&#xA0; 560 mm x 1285 mm&#xA0;</description><thumbnail_url>https://ptmajujayamedika.co.id/wp-content/uploads/2025/03/AMULET-BELLUS-II.png</thumbnail_url></oembed>
